This study was carried out to assess indoor air quality (IAQ) in schools in Akwa Ibom State of Nigeria during the rainy (June – July) and dry (November – December) seasons of 2018. IAQ parameters were examined to assess pollutant levels in schools within Akwa Ibom State in single setting only (naturally ventilated classrooms). Schools were randomly selected from two zones: zone 1 which is located within the Capital City (Uyo metropolis) and represents the 'urban sector', and zone 2 which is located within the southern part of the state in close proximity to the oil and gas industrial region and represents the 'industrial sector'. Indoor air investigation included the following parameters: particulate matter (PM1, PM2, PM5, and PM10), carbon monoxide (CO), carbon dioxide (CO2) levels, temperature and relative humidity, which were simultaneously measured in fourteen (14) sampling days using Fluke 985 Particle Counter and Fluke 975 AirMeter. Multiple statistically analysis techniques were used to compare IAQ parameters and test for significant differences between the zones (urban vs. industrial) and annual seasonal variations. The concentrations of particulate matter (PM) in the naturally ventilated classroom in industrial zone during the rainy season ranged from 5152 – 5984 μg/m3 for PM1; 2744 – 3207 μg/m3 for PM2; 137 – 149 μg/m3 for PM5; 38 – 46 μg/m3 for PM10 and in urban zone, the concentrations of PM ranged from 1978 – 2491 μg/m3 for PM1; 1010 – 1311 μg/m3 for PM2; 38 – 56 μg/m3 for PM5; 15 – 24 μg/m3 for PM10. During the dry season, the concentrations of PM in the naturally ventilated classroom in industrial zone ranged from 6138 – 6999 μg/m3 for PM1; 2984 – 3980 μg/m3 for PM2; 146 – 159 μg/m3 for PM5; 47 – 59 μg/m3 for PM10 and in urban zone, the concentrations of PM ranged from 2556 – 3972 μg/m3 for PM1; 1911 – 2311 μg/m3 for PM2; 51 – 66 μg/m3 for PM5; 18 – 34 μg/m3 for PM10. Results of this study has revealed that the concentrations of PM1, PM2, PM5, and PM10 measured in the naturally ventilated classroom in industrial zone were significantly (p < 0.001) higher than those measured in the urban zone during both rainy and dry seasons. In this present study, the concentrations of PM10 measured were found to be much lower than the ambient maximum contaminant level for airborne PM10 standard promulgated by the United States Environmental Protection Agency (US–EPA) (150 μg/m3 daily average and 50 μg/m3 annual average) and World Health Organization (WHO) PM10 guidelines values (50 μg/m3 daily average and 20 μg/m3 annual average). Apart from re–suspension of atmospheric particles, anthropogenic activities in industrial zone significantly influenced the measured concentrations of PM compared to those measured in urban zone. In addition, the lower concentration of CO and CO2 measured indicated adequate air exchange at the time of the assessment in the naturally ventilated classrooms during the sampling period. The results obtained reveal important contributions towards understanding of airborne PM distribution patterns and the available data can be used for making public health policies.
Air pollution associated with natural and/or anthropogenic activities may cause adverse effects on human health and the environment. Over the past sixty years, advances in industrialization, urbanization, large volume of emissions from vehicles, and other activities in the petroleum industry associated with exploration and production of energy and/or chemicals have resulted in air pollution around the world 1, 2, 3. According to Ite & Ibok 1, gas flaring and venting of petroleum–associated gas in the petroleum industry in the Nigeria’s Niger Delta has clearly impacted on the natural environment, human health, socio–economic environment and caused degradation of host communities. In addition, increasing energy consumption in terms of combustion of fossil fuels in the last century is responsible for the progressive change in the atmospheric composition as well as atmospheric pollution 4. Most of the atmospheric pollutants, such as carbon monoxide (CO), sulphur dioxide (SO2), nitrogen oxides (NOx), volatile organic compounds (VOCs), ozone (O3), heavy metals, and respirable particulate matter (PM2.5 and PM10), differ in their chemical composition, reaction properties, time of disintegration and poor atmospheric dispersion conditions 4, 5. As a result, the particulate matter (the suspended material of the atmosphere) in both developed and developing countries has been heavily impacted over the years. Particulate matter (PM) is a complex mixture of extremely small particles (solids) and liquid droplets of primary and secondary origin that contain a wide range of inorganic and organic components 6, 7. It is known that the size distribution of PM in an ambient air is trimodal according to the aerodynamic diameter 8.
Although PM is found in both outdoor and indoor environment, coarse and fine particles sum up to particles with an aerodynamic diameter less than 10 μm (PM10). PM can be suspended over long period of time and travel over long distances in the atmosphere, and as such significantly affect local and/or regional air quality, human health and climate change. It is known that the spatial and temporal distribution of PM is variable and is strongly influenced by both climatic and meteorological conditions 7, 9, 10. Indoor air quality (IAQ) is a continuing concern for students, parents, teachers, and school staff, leading to many complaints regarding poor IAQ in many developed countries around the world 11. Over the years, several research work has been published with respect to IAQ in schools in both developed and developing countries around the world 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23. Some of the human health implications associated with PM pollutions in schools are as follows: higher susceptibility of children to environmental pollutants 24, 25, 26, higher inhalation rates per body mass 27, 28, and longer time spent in schools 26, 28. Findings from several studies have identified different pollutant parameters that contribute to IAQ problems in some schools around the world. For example, high PM10 and CO2 levels in Porto, Portugal 12, Hong Kong 13 and Munich, Germany 14, Kosice, Slovakia 15, Qatari 26; high mean concentrations of both PM10 and PM2.5 in Lahore, Pakistan 16; higher mean indoor CO2 concentration than the ASHRAE standards-62 17 of 1000 ppm in Athens, Greece 18, 19, and Serbia 20, or the CO2 value established by Portuguese legislation 21; high CH2O concentration emitted by building materials or furnishings in South Korea 22 and France 23; and high average SO2 concentrations in French schools 29.
Human health effects associated with both indoor and outdoor environmental air pollutants have been of great concern due to the high exposure risk even at relatively low concentrations of the air pollutants 30. Evidence continues to emerge showing that exposure to airborne pollutants and/or poor IAQ can cause adverse human health complications requiring absence from schools, and can cause acute health symptoms that decrease students’ performance 21. Over the past decades, several epidemiological studies and the adverse human health effects associated with PM pollution have been documented across the world 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45. According to Brunekreef & Holgate 45, these effects have been reported in short-term studies, which relate day-to-day variations in air pollution and health, and long-term studies, which have followed cohorts of exposed individuals over time. Therefore, good indoor air quality in classrooms provides healthy learning environment to children, promotes learning ability and also helps to make teachers as well as staff to be more productive 46. Some of the main factors affecting indoor environment include temperature, humidity, air exchange rate, air movement, ventilation, particle pollutants, biological pollutants, and gaseous pollutants 47. Although PM–related air pollution affects cardiorespiratory health, it is unclear which particle size fractions and sources of particles are responsible for the human health effects 38, 40, 44.
The exposure to ambient PM pollution is a major threat to public health and poor indoor air quality can cause a wide range of health–related symptoms that may lead to a significant reduction in human productivity as well as increased mortality. However, information about indoor conditions of school classrooms in Akwa Ibom State are limited and availability of IAQ data is important as children are vulnerable to health hazards and spend long times in classrooms. Therefore, the present study investigates indoor air quality in schools in urban and industrial (Oil & Gas) zones in Akwa Ibom State of Nigeria during the rainy (June – July) and dry (November – December) seasons of 2018.
This study was carried out in naturally ventilated classroom in Urban Zone (Uyo Local Government Area) and in Industrial Zone (Ikot Abasi Local Government Area) in Akwa Ibom State of Nigeria (Figure 1). Akwa Ibom State, which is currently the largest oil–producing state in the Nigeria’s Niger Delta region, is located in the coastal southern part of the country (i.e. South–South geopolitical zone). Akwa Ibom State covers a total land area of 8412 km2 and lies between latitudes 4°32′N and 5°33′N, and longitudes 7°25′E and 8°25′E. The state is bordered on the east by Cross River State, on the west by Rivers State and Abia State, and on the south by the Atlantic Ocean and the southernmost tip of Cross River State.
Uyo, which is the capital of Akwa Ibom State, is situated between latitude 5o 01' North of Equator and longitude 7o 56' East of the Meridian. It is bounded in the west by Abak, east by Uruan, north by Ikono, Ibiono Ibom and Itu and in the south by Etinan, Ibesikpo/Asutan and Nsit Ibom Local Government Areas.
Ikot Abasi is a local government area in Akwa Ibom State with an area of approximately 451.73 km². Ikot Abasi is located in the south west corner of Akwa Ibom State, Nigeria. It is bounded by Oruk Anam Local Government Area in the north, Mkpat Enin and Eastern Obolo Local Government Areas in the east and the Atlantic Ocean in the south. The Imo River forms the natural boundary in the west separating it from Rivers State. Ikot Abasi is a home to Aluminium Company of Nigeria (ALSCON) – the biggest aluminium smelter plant in Africa and Ibom Power Company (IPC) – the first independent power plants in Nigeria.
Figure 1 shows location maps for the two selected school zones in the study. Indoor air quality parameters were measured in one school randomly selected from two different zones in Akwa Ibom State; zone 1 is State Capital (Uyo Metropolis) which represents the urban sector, and zone 2 is located further south in close proximity to the oil and gas industrial region which represents the industrial sector. The present research was carried out in naturally ventilated classroom in industrial and in urban zones located within Akwa Ibom State of Nigeria. The windows in the classrooms were kept opened during the assessment period. The characteristics of the classrooms selected for the study are presented in Table 1.
IAQ parameters measurements were carried out for 14 days in two campaigns performed in June – July (rainy season) and November – December (dry season) of 2018. The indoor PM1, PM2, PM5, and PM10 mass concentrations were monitored simultaneously using Fluke 985 Particle Counter with with six channels and particle size range of 0.3 – 10.0 µm (Fluke Corporation, United Kingdom) 7. In addition, the Fluke 975 AirMeter manufactured by Fluke Corporation (United Kingdom) was used to simultaneously measure, logs, and display temperature, relative humidity, CO2, and CO concentrations. The Fluke 975 AirMeter automatically compensates for barometric pressure changes and has an extensive discrete or continuous data logging capacity. In this present study, the measuring instruments were located approximately 1 m away from walls and mounted on a flat surface with a height of 1.5 m in order to simulate school children breathing zone 48, 49, 50.
2.3. Statistical AnalysisMultiple statistically analysis techniques were used to compare IAQ parameters and test for significant differences between the zones (urban vs. industrial) and annual seasonal variations. Descriptive statistics were used to characterize the measured IAQ parameters and T-test was conducted to compare differences between the two zones (urban vs. industrial) and annual seasons for particulate matter (PM1, PM2, PM5, and PM10), carbon monoxide (CO), carbon dioxide (CO2) levels, temperature and relative humidity. One-way ANOVA was used to make comparisons by seasons and locations for particulate matter (PM1, PM2, PM5, and PM10), carbon monoxide (CO), and carbon dioxide (CO2) levels. Statistical analyses were conducted to determine and evaluate the impact of relevant parameters on the particle concentrations and students’ exposure in the naturally ventilated classroom. A value of p < 0.05 was considered statistically significant. All data analyses were carried out and the airborne PM distribution profiles are presented using a scientific data analysis and graphing software package – SigmaPlot®, Version 14 (Systat Software Inc., USA).
Among the indoor air quality parameters monitored, PM concentrations were found to be significantly higher in the naturally ventilated classroom in industrial zone compared to urban zone. The low CO and CO2 levels measured indicate adequate ventilation in the naturally ventilated classroom in industrial and urban zones during the assessment period. Table 2 presents the descriptive statistics of daily average IAQ parameters and other measured comfort parameters during the assessment period. Correlation matrix among PM1, PM2, PM5, PM10 concentrations and other indoor air quality parameters in a naturally ventilated classroom in industrial and urban zones are presented in Table 3 – Table 6. The data were grouped into two periods: the rainy season (June – July) and dry season (November – December) of 2018. The seasonal variations of PM (PM1, PM2, PM5, and PM10) concentrations in both naturally ventilated classroom in industrial and urban zones during rainy and dry seasons are graphical shown in Figure 2 – Figure 5.
The concentrations of particulate matter (PM) in the naturally ventilated classroom in industrial zone during the rainy season ranged from 5152 – 5984 μg/m3 for PM1; 2744 – 3207 μg/m3 for PM2; 137 – 149 μg/m3 for PM5; 38 – 46 μg/m3 for PM10 and in urban zone, the concentrations of PM ranged from 1978 – 2491 μg/m3 for PM1; 1010 – 1311 μg/m3 for PM2; 38 – 56 μg/m3 for PM5; 15 – 24 μg/m3 for PM10. During the dry season, the concentrations of PM in the naturally ventilated classroom in industrial zone ranged from 6138 – 6999 μg/m3 for PM1; 2984 – 3980 μg/m3 for PM2; 146 – 159 μg/m3 for PM5; 47 – 59 μg/m3 for PM10 and in urban zone, the concentrations of PM ranged from 2556 – 3972 μg/m3 for PM1; 1911 – 2311 μg/m3 for PM2; 51 – 66 μg/m3 for PM5; 18 – 34 μg/m3 for PM10. Results of this study has revealed that the concentrations of PM1, PM2, PM5, and PM10 measured in the naturally ventilated classroom in industrial zone were significantly (p < 0.001) higher than those measured in urban zone during both rainy and dry seasons. Based on the results of correlation analysis, for the pairs with negative correlation coefficients and P values below 0.050, one variable tends to decrease while the other increases. For pairs with P values greater than 0.050, there were no significant relationship between the two variables. In this present study, the concentrations of PM10 measured were found to be much lower than the ambient maximum contaminant level for airborne PM10 standard promulgated by the United States Environmental Protection Agency (US–EPA) (150 μg/m3 daily average and 50 μg/m3 annual average) and World Health Organization (WHO) PM10 guidelines values (50 μg/m3 daily average and 20 μg/m3 annual average). The WHO suggest Global Air–Quality Guideline values as follows 10 μg/m3 annual mean, 25 μg/m3 24-hour mean for PM2.5 and 20 μg/m3 annual mean, 50 μg/m3 24-hour mean for PM10 51. Findings from related studies have shown that human activities may act as an important indoor source for PM in classrooms considering that the occupant density in the schools was several times higher than those measured in the other buildings 14, 52, 53. In the present study, it was found that indoor PM10 concentrations varied significantly with occupant’s activities and higher PM10 concentrations were observed in naturally ventilated classroom in industrial zone. The high PM10 concentrations measured in this study could be attributed to resuspension of previously deposited airborne particles and their delayed deposition associated with physical activity of the students 7, 21, 54, 55, 56. In a classroom environment, there are several important sources of particles and these include mineral dust, building materials and chalk 21. It has been reported that even low activity can have a significant impact on the concentration of airborne particles with diameters greater than 5 μm 55.
Over the years, several studies have been conducted with the aim of understanding indoor air quality of school environment across the world 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 26, 52, 53, 54, 56, 57, 58, 59, 60, 61, 62, 63. In a study, Tippayawong et al. 62 found that the highest concentrations were measured for particles in the 0.3 – 0.5 μm size range with an average value of 180 cm-3 while the lowest concentrations were measured in the 2.5 – 5 μm size range with an average of 0.05 cm-3. In a related study, Parker et al. 63 reported that while the smallest particle (0.3 – 0.4 μm) concentrations remained relatively constant over a day between about 4 and 8 cm-3, coarse particles (7.5 – 10 μm) rose with occupancy from zero to about 0.025 cm-3 during typical days. The building studied by Tippayawong et al. 62 was naturally ventilated and had higher concentrations than those measured in this study, while Parker et al. 63 studied a mechanically ventilated building which had lower concentrations. In a related study, Lee and Chang 13 investigated IAQ of five classrooms in Hong Kong and reported that the average respirable suspended particulate matter (RSPM) concentrations were higher than the Hong Kong air quality objective and the maximum indoor PM10 level which exceeded 1000 μg/m3. In the present study, the investigation of IAQ was carried out in an naturally ventilated classrooms and the windows were kept opened at all times during the school hours. It has been observed that the IAQ of the school building could be influenced by outdoor pollutant sources 64 and the PM concentrations measured in the present might have been affected by anthropogenic activities (e.g. industrial activities associated with petroleum industry, fossil fuel combustion and traffic–related emissions) within the surrounding environment. Review of findings from various studies investigating particulate matter in ambient air at selected locations in Nigeria from 1985 – 2015 showed that PM2.5 concentration ranged from 5 – 248 μg/m3 and PM10 concentration ranged from 18 – 926 μg/m3 65. According to Offor et al. 65, about 50% of the outdoor PM concentrations in Nigeria exceeded both the WHO (25 μg/m3, 50 μg/m3) and National Ambient Air Quality Standards (NAAQs) (35 μg/m3, 150 μg/m3) guideline limits for PM2.5 and PM10, respectively. Based on the PM2.5/PM10 ratios (which fall below the WHO guideline, 0.5 – 0.8) for the selected outdoor studies, it has been observed that the aerosols in Nigerian environment are mainly made up of more coarse particles and less fraction of fine particles. In a study, it has been observed that built-up areas of Nigerian cities are characterised with high levels of annual mean ambient airborne PM10 concentration of > 120 µg/m3 while rural areas had annual mean ambient PM10 values of 57.4 µg/m3 66.
In this present study, the mean daily indoor concentrations of CO measured in naturally ventilated classrooms in industrial and in urban zones during the assessment period were less than the 1– and 8–h standards set by the US-EPA of 35 and 9 ppm, respectively 67. Similarly, the mean daily indoor concentrations of CO in all naturally ventilated classrooms in industrial and in urban zones during the assessment period were also less than the 1– and 8–h WHO guidelines of 30.60 and 8.60 ppm, respectively 68. CO, toxic air pollutant, is produced in the incomplete combustion of carbon-containing fuels, such as gasoline, natural gas, oil, coal, and wood. The largest anthropogenic source of CO in the developed and developing countries is traffic related air pollutants in urban areas and other industrial emissions associated with incomplete combustion of fossil fuels (e.g. gas flaring and venting). CO occurs indoors either directly as a result of emissions from various indoor sources or indirectly as a result of infiltration of CO from outdoor air into the indoor environment (e.g. from vehicles in major roads nearby, wastes burning) 68, 69, 70. In this study, there were no significant indoor sources of CO observed in naturally ventilated classrooms under investigation during the monitoring campaign.
In this study, the slight elevated concentration of the indoor CO2 concentrations was likely from traffic emissions and /or other sources. However, there were no significant correlation between indoor CO and CO2 concentrations suggesting that both have different sources of emissions. However, other researchers have attributed high CO2 levels in classrooms to indoor sources associated with a result of high occupancy combined with inadequate ventilation 22, 26, 71. Therefore, high number of students combined with small classroom volumes and poor ventilation could considerably increase indoor CO2 concentrations over a long period of time. Apart from emissions in the industrial and urban zones in Akwa Ibom State, the findings reveal that a large fraction of students might have been exposed to poor IAQ and traffic-related pollutants over a long period of time. Therefore, there is a need for exposure measures that account for both the composition and volume of traffic in some part of the Nigeria’s Niger Delta region.
The ANSI/ASHRAE Standard 55-2013 72 specifies the combination of indoor environmental and personal factors that produce acceptable thermal conditions to a majority of occupants within a space. According to the US–EPA recommendations, maintaining indoor RH between 30% and 50% (< 60%) is ideal in order to control mould growth 67. In this present study, indoor temperature and RH were not entirely in accordance with international standards. Therefore, policies should be put in place to regulate and maintain effective control of temperature and RH in classrooms in order to comply with ANSI/ASHRAE Standard 55-2013. Generally, there is scarcity of information about indoor conditions of classrooms in Akwa Ibom State schools and availability of IAQ data is important as children are vulnerable to health hazards and spend long times in classrooms. Although air pollution has mainly been associated with pulmonary diseases and cardiorespiratory disorders 45, limited experimental and epidemiological data suggest that air pollutants may also exert deleterious gastrointestinal effects 73. Potential mechanisms by which air pollutants may cause intestinal injury are thought to include direct adverse effects on epithelial cells, alterations in immune responses, or modulation of the gut microbiota 73, 74, 75, 76. Air pollution exposure has also been shown to impair lung function development in children 77. Based on the findings of a study by Salim et al. 76, it has been suggested that early exposure to particulate matter pollution can result in an earlier onset of intestinal disease in genetically susceptible hosts and can alter responses to gut injury in later life. In addition, air pollution has also been associated with a variety of non-pulmonary diseases including myocardial infarction 78, appendicitis 79, and rheumatoid arthritis 80. Air pollution-mediated inflammation has been implicated as the cause of several adverse health effects 81. Over the past years, scientific evidences from several epidemiological and experimental studies have demonstrated that short-term and long-term exposure to particulate matter is often associated with cardiopulmonary injury and systemic diffusion 82.
The PM concentrations were significantly higher in naturally ventilated classroom in industrial zone compared to those in urban zone. The higher PM concentration in the naturally ventilated classroom in industrial zone could be attributed to various anthropogenic activities, industrial emissions associated with petroleum industry, power generation as well as re–suspension of dust. In addition, the long distant transport of pollutants into industrial zone atmosphere from the neighbouring state (Rivers State) might have accounted for a significant portion of the regional PM pollution. Findings from this study have shown significant seasonal variations of PM distributions and naturally ventilated classroom in industrial zone had the highest concentration of PM compared to the naturally ventilated classroom in urban zone. Generally, the PM fractions decreased in the rainy season and increased in the dry season. Since there is no evidence of a safe level of PM exposure, high concentrations of respirable particles in classroom can adversely affect human health, students’ performance and productivity. The results obtained from this study suggest the need for effective management of indoor air quality in schools and there is an urgent need for routine air monitoring data on components of the PM mass. Availability of IAQ data are essential to enable epidemiological studies that can define the roles of PM chemical components in causing adverse human health implications in order to guide more targeted emission controls for the most hazardous components. The results obtained reveal important contributions towards understanding of airborne PM distribution patterns and the available data that can be used for making public health policies. However, more comprehensive studies are required with more regional attributions and continuous measurements to fully evaluate the air quality of most part of the Nigeria’s Niger Delta region. In addition, it is necessary to take other gaseous pollutants into consideration to determine the general air quality in various school environment in Akwa Ibom State.
The authors would like to thank Engr. Emem E. Ite of Infiniti Innovative Group – USA and the Research & Development (R&D) Unit of Akwa Ibom State University – Nigeria for providing all the support for successful completion of this research.
[1] | Ite, A. E., and U. J. Ibok, “Gas Flaring and Venting Associated with Petroleum Exploration and Production in the Nigeria's Niger Delta,” American Journal of Environmental Protection, 1 (4). 70-77, 2013. | ||
In article | View Article | ||
[2] | Ite, A. E., U. J. Ibok, M. U. Ite, and S. W. Petters, “Petroleum Exploration and Production: Past and Present Environmental Issues in the Nigeria's Niger Delta,” American Journal of Environmental Protection, 1 (4). 78-90, 2013. | ||
In article | View Article | ||
[3] | Ite, A. E., U. F. Ufot, M. U. Ite, I. O. Isaac, and U. J. Ibok, “Petroleum Industry in Nigeria: Environmental Issues, National Environmental Legislation and Implementation of International Environmental Law,” American Journal of Environmental Protection, 4 (1). 21-37, 2016. | ||
In article | |||
[4] | Kampa, M., and E. Castanas, “Human health effects of air pollution,” Environmental Pollution, 151 (2). 362-367, 2008. | ||
In article | View Article PubMed | ||
[5] | Kelly, F. J., G. W. Fuller, H. A. Walton, and J. C. Fussell, “Monitoring air pollution: use of early warning systems for public health,” Respirology, 17 (1). 7-19, 2012. | ||
In article | View Article PubMed | ||
[6] | Lippmann, M., “Particulate matter (PM) air pollution and health: regulatory and policy implications,” Air Quality, Atmosphere & Health, 5 (2). 237-241, 2011. | ||
In article | View Article | ||
[7] | Ite, A. E., C. O. Ogunkunle, C. O. Obadimu, E. R. Asuaiko, and U. J. Ibok, “Particulate Matter and Staff Exposure in an Air-Conditioned Office in Akwa Ibom State University - Nigeria,” Journal of Atmospheric Pollution, 5 (1). 24-32, 2017. | ||
In article | View Article | ||
[8] | Cohen, A. J., H. R. Anderson, B. Ostro, K. D. Pandey, M. Krzyzanowski, N. Künzli, K. Gutschmidt, C. Pope III, I. Romieu, and J. M. Samet, “Urban Air Pollution,” Comparative Quantification of Health Risks: Global and Regional Burden of Disease Attributable to Selected Major Risk Factors, M. Ezzati, A. Lopez, A. Rodgers and C. J. L. Murray, eds., pp. 1353-1433, Geneva: World Health Organization, 2004. | ||
In article | |||
[9] | Wiseman, C. L. S., and F. Zereini, “Part I - Airborne Particulate Matter: Sources, Composition and Concentration,” Urban Airborne Particulate Matter: Origin, Chemistry, Fate and Health Impacts, F. Zereini and C. L. S. Wiseman, eds., pp. 1-2, Berlin, Heidelberg: Springer Berlin Heidelberg, 2011. | ||
In article | |||
[10] | Pöschl, U., “Atmospheric Aerosols: Composition, Transformation, Climate and Health Effects,” Angewandte Chemie International Edition, 44 (46). 7520-7540, 2005. | ||
In article | View Article PubMed | ||
[11] | Godwin, C., and S. Batterman, “Indoor air quality in Michigan schools,” Indoor Air, 17 (2). 109-121, 2007. | ||
In article | View Article PubMed | ||
[12] | Madureira, J., I. Paciência, C. Pereira, J. P. Teixeira, and E. d. O. Fernandes, “Indoor air quality in Portuguese schools: levels and sources of pollutants,” 26 (4). 526-537, 2016. | ||
In article | View Article PubMed | ||
[13] | Lee, S. C., and M. Chang, “Indoor and outdoor air quality investigation at schools in Hong Kong,” Chemosphere, 41 (1). 109-113, 2000. | ||
In article | View Article | ||
[14] | Fromme, H., D. Twardella, S. Dietrich, D. Heitmann, R. Schierl, B. Liebl, and H. Rüden, “Particulate matter in the indoor air of classrooms—exploratory results from Munich and surrounding area,” Atmospheric Environment, 41 (4). 854-866, 2007. | ||
In article | View Article | ||
[15] | Vilčeková, S., P. Kapalo, Ľ. Mečiarová, E. K. Burdová, and V. Imreczeová, “Investigation of Indoor Environment Quality in Classroom - Case Study,” Procedia Engineering, 190 496-503, 2017. | ||
In article | View Article | ||
[16] | Yousaf, A. R., and N. Khan, “The study of particulate matter concentration in schools of Lahore,” Nature Environment and Pollution Technology, 12 (2). 289-296, 2013. | ||
In article | |||
[17] | Moschandreas, D. J., and K. L. Vuilleumier, “ETS levels in hospitality environments satisfying ASHRAE standard 62-1989: “ventilation for acceptable indoor air quality”,” Atmospheric Environment, 33 (26). 4327-4340, 1999. | ||
In article | View Article | ||
[18] | Santamouris, M., A. Synnefa, M. Asssimakopoulos, I. Livada, K. Pavlou, M. Papaglastra, N. Gaitani, D. Kolokotsa, and V. Assimakopoulos, “Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation,” Energy and Buildings, 40 (10). 1833-1843, 2008. | ||
In article | View Article | ||
[19] | Synnefa, A., E. Polichronaki, E. Papagiannopoulou, M. Santamouris, G. Mihalakakou, P. Doukas, P. A. Siskos, E. Bakeas, A. Dremetsika, A. Geranios, and A. Delakou, “An Experimental Investigation of the Indoor Air Quality in Fifteen School Buildings in Athens, Greece,” International Journal of Ventilation, 2 (3). 185-201, 2003. | ||
In article | View Article | ||
[20] | Jovanović, M., B. Vučićević, V. Turanjanin, M. Živković, and V. Spasojević, “Investigation of indoor and outdoor air quality of the classrooms at a school in Serbia,” Energy, 77 42-48, 2014. | ||
In article | View Article | ||
[21] | Almeida, S. M., N. Canha, A. Silva, M. d. C. Freitas, P. Pegas, C. Alves, M. Evtyugina, and C. A. Pio, “Children exposure to atmospheric particles in indoor of Lisbon primary schools,” Atmospheric Environment, 45 (40). 7594-7599, 2011. | ||
In article | View Article | ||
[22] | Yang, W., J. Sohn, J. Kim, B. Son, and J. Park, “Indoor air quality investigation according to age of the school buildings in Korea,” Journal of Environmental Management, 90 (1). 348-354, 2009. | ||
In article | View Article PubMed | ||
[23] | Verriele, M., C. Schoemaecker, B. Hanoune, N. Leclerc, S. Germain, V. Gaudion, and N. Locoge, “The MERMAID study: indoor and outdoor average pollutant concentrations in 10 low-energy school buildings in France,” 26 (5). 702-713, 2016. | ||
In article | View Article PubMed | ||
[24] | Cartieaux, E., M. A. Rzepka, and D. Cuny, “Qualité de l’air à l’intérieur des écoles,” Archives de Pediatrie, 18 (7). 789-796, 2011. | ||
In article | View Article PubMed | ||
[25] | Nkwocha, E. E., R. O. J. I. J. o. E. S. Egejuru, and Technology, “Effects of industrial air pollution on the respiratory health of children,” 5 (4). 509-516, 2008. | ||
In article | View Article | ||
[26] | Abdel-Salam, M. M. M., “Investigation of indoor air quality at urban schools in Qatar,” Indoor and Built Environment, 28 (2). 278-288, 2017. | ||
In article | View Article | ||
[27] | de Gennaro, G., P. R. Dambruoso, A. D. Loiotile, A. Di Gilio, P. Giungato, M. Tutino, A. Marzocca, A. Mazzone, J. Palmisani, and F. J. E. C. L. Porcelli, “Indoor air quality in schools,” 12 (4). 467-482, 2014. | ||
In article | View Article | ||
[28] | de Gennaro, G., P. R. Dambruoso, A. D. Loiotile, A. Di Gilio, P. Giungato, M. Tutino, A. Marzocca, A. Mazzone, J. Palmisani, and F. Porcelli, “Indoor air quality in schools,” Environmental Chemistry Letters, 12 (4). 467-482, 2014. | ||
In article | View Article | ||
[29] | Meininghaus, R., A. Kouniali, C. Mandin, and A. Cicolella, “Risk assessment of sensory irritants in indoor air—a case study in a French school,” Environment International, 28 (7). 553-557, 2003. | ||
In article | View Article | ||
[30] | Kim, K.-H., E. Kabir, and S. Kabir, “A review on the human health impact of airborne particulate matter,” Environment International, 74 136-143, 2015. | ||
In article | View Article PubMed | ||
[31] | Celo, V., and E. Dabek-Zlotorzynska, “Concentration and Source Origin of Trace Metals in PM2.5 Collected at Selected Canadian Sites within the Canadian National Air Pollution Surveillance Program,” Urban Airborne Particulate Matter: Origin, Chemistry, Fate and Health Impacts, F. Zereini and C. L. S. Wiseman, eds., pp. 19-38, Berlin, Heidelberg: Springer Berlin Heidelberg, 2011. | ||
In article | View Article | ||
[32] | Iavicoli, I., V. Leso, L. Fontana, and A. Bergamaschi, “Occupational Exposure to Urban Airborne Particulate Matter: A Review on Environmental Monitoring and Health Effects,” Urban Airborne Particulate Matter: Origin, Chemistry, Fate and Health Impacts, F. Zereini and C. L. S. Wiseman, eds., pp. 501-525, Berlin, Heidelberg: Springer Berlin Heidelberg, 2011. | ||
In article | View Article PubMed PubMed | ||
[33] | Jahn, H. J., A. Schneider, S. Breitner, R. Eißner, M. Wendisch, and A. Krämer, “Particulate matter pollution in the megacities of the Pearl River Delta, China – A systematic literature review and health risk assessment,” International Journal of Hygiene and Environmental Health, 214 (4). 281-295, 2011. | ||
In article | View Article PubMed | ||
[34] | Calkovska, A., and E. Herting, “Exogenous surfactant in respiratory distress syndrome,” Applied Technologies in Pulmonary Medicine, A. M. Esuinas, ed., pp. 205-209, Basel: Karger Publishers, 2010. | ||
In article | View Article | ||
[35] | Frew, A. J., S. R. Doffman, K. Hurt, and R. Buxton-homas, “Respiratory Disease,” Kumar & Clark Clinical Medicine, P. J. Kumar and M. L. Clark, eds., pp. 791-866, Saunders: Elsevier 2005. | ||
In article | |||
[36] | Guaita, R., M. Pichiule, T. Mate, C. Linares, and J. Diaz, “Short-term impact of particulate matter (PM(2.5)) on respiratory mortality in Madrid,” International Journal of Environmental Health Research, 21 (4). 260-274, 2011. | ||
In article | View Article PubMed | ||
[37] | Janssen, N. A. H., P. Fischer, M. Marra, C. Ameling, and F. R. Cassee, “Short-term effects of PM2.5, PM10 and PM2.5–10 on daily mortality in the Netherlands,” Science of the Total Environment, 463–464 20-26, 2013. | ||
In article | View Article PubMed | ||
[38] | Halonen, J. I., T. Lanki, T. Yli-Tuomi, P. Tiittanen, M. Kulmala, and J. Pekkanen, “Particulate air pollution and acute cardiorespiratory hospital admissions and mortality among the elderly,” Epidemiology, 20 (1). 143-153, 2009. | ||
In article | View Article PubMed | ||
[39] | Du, Y., X. Xu, M. Chu, Y. Guo, and J. Wang, “Air particulate matter and cardiovascular disease: the epidemiological, biomedical and clinical evidence,” Journal of Thoracic Disease, 8 (1). E8-E19, 2016. | ||
In article | |||
[40] | Brook, R. D., S. Rajagopalan, C. A. Pope, J. R. Brook, A. Bhatnagar, A. V. Diez-Roux, F. Holguin, Y. Hong, R. V. Luepker, and M. A. Mittleman, “Particulate matter air pollution and cardiovascular disease,” Circulation, 121 (21). 2331-2378, 2010. | ||
In article | View Article PubMed | ||
[41] | Pope, C. A., and D. W. Dockery, “Health Effects of Fine Particulate Air Pollution: Lines that Connect,” Journal of the Air & Waste Management Association, 56 (6). 709-742, 2006. | ||
In article | View Article | ||
[42] | Davidson, C. I., R. F. Phalen, and P. A. Solomon, “Airborne Particulate Matter and Human Health: A Review,” Aerosol Science and Technology, 39 (8). 737-749, 2005. | ||
In article | View Article | ||
[43] | Linares, C., and J. Diaz, “Short-term effect of concentrations of fine particulate matter on hospital admissions due to cardiovascular and respiratory causes among the over-75 age group in Madrid, Spain,” Public Health, 124 (1). 28-36, 2010. | ||
In article | View Article PubMed | ||
[44] | Strak, M., G. Hoek, M. Steenhof, E. Kilinc, K. J. Godri, I. Gosens, I. S. Mudway, R. van Oerle, H. M. H. Spronk, F. R. Cassee, F. J. Kelly, R. M. Harrison, B. Brunekreef, E. Lebret, and N. A. H. Janssen, “Components of ambient air pollution affect thrombin generation in healthy humans: the RAPTES project,” Occupational and Environmental Medicine, 70 (5). 332-340, 2013. | ||
In article | View Article PubMed | ||
[45] | Brunekreef, B., and S. T. Holgate, “Air pollution and health,” Lancet, 360 (9341). 1233-1242, 2002. | ||
In article | View Article | ||
[46] | Heudorf, U., V. Neitzert, and J. Spark, “Particulate matter and carbon dioxide in classrooms – The impact of cleaning and ventilation,” International Journal of Hygiene and Environmental Health, 212 (1). 45-55, 2009. | ||
In article | View Article PubMed | ||
[47] | Graudenz, G. S., C. H. Oliveira, A. Tribess, C. Mendes, M. R. D. O. Latorre, and J. Kalil, “Association of air-conditioning with respiratory symptoms in office workers in tropical climate,” Indoor Air, 15 (1). 62-66, 2005. | ||
In article | View Article PubMed | ||
[48] | Al-Hemoud, A., L. Al-Awadi, M. Al-Rashidi, K. A. Rahman, A. Al-Khayat, and W. Behbehani, “Comparison of indoor air quality in schools: Urban vs. Industrial 'oil & gas' zones in Kuwait,” Building and Environment, 122 50-60, 2017. | ||
In article | View Article | ||
[49] | Cavaleiro Rufo, J., J. Madureira, I. Paciencia, K. Slezakova, C. Pereira Mdo, L. Aguiar, J. P. Teixeira, A. Moreira, and E. Oliveira Fernandes, “Children exposure to indoor ultrafine particles in urban and rural school environments,” Environ Sci Pollut Res Int, 23 (14). 13877-13885, 2016. | ||
In article | View Article PubMed | ||
[50] | Jo, W.-K., and J.-Y. Lee, “Indoor and outdoor levels of respirable particulates (PM10) and Carbon Monoxide (CO) in high-rise apartment buildings,” Atmospheric Environment, 40 (32). 6067-6076, 2006. | ||
In article | View Article | ||
[51] | WHO, Air Quality Guidelines: Global Update 2005: Particulate Matter, Ozone, Nitrogen dioxide, and Sulfur dioxide, Copenhagen, Denmark: World Health Organization, 2006. | ||
In article | |||
[52] | Goyal, R., and M. Khare, “Indoor–outdoor concentrations of RSPM in classroom of a naturally ventilated school building near an urban traffic roadway,” Atmospheric Environment, 43 (38). 6026-6038, 2009. | ||
In article | View Article | ||
[53] | Tippayawong, N., P. Khuntong, C. Nitatwichit, Y. Khunatorn, and C. Tantakitti, “Indoor/outdoor relationships of size-resolved particle concentrations in naturally ventilated school environments,” Building and Environment, 44 (1). 188-197, 2009. | ||
In article | View Article | ||
[54] | Chithra, V. S., and S. M. Shiva Nagendra, “Indoor air quality investigations in a naturally ventilated school building located close to an urban roadway in Chennai, India,” Building and Environment, 54 159-167, 2012. | ||
In article | View Article | ||
[55] | Thatcher, T. L., and D. W. Layton, “Deposition, resuspension, and penetration of particles within a residence,” Atmospheric Environment, 29 (13). 1487-1497, 1995. | ||
In article | View Article | ||
[56] | Kalimeri, K. K., D. E. Saraga, V. D. Lazaridis, N. A. Legkas, D. A. Missia, E. I. Tolis, and J. G. Bartzis, “Indoor air quality investigation of the school environment and estimated health risks: Two-season measurements in primary schools in Kozani, Greece,” Atmospheric Pollution Research, 7 (6). 1128-1142, 2016. | ||
In article | View Article | ||
[57] | Mendell, M. J., and G. A. Heath, “Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature,” Indoor Air, 15 (1). 27-52, 2005. | ||
In article | View Article PubMed | ||
[58] | Shendell, D. G., R. Prill, W. J. Fisk, M. G. Apte, D. Blake, and D. Faulkner, “Associations between classroom CO2 concentrations and student attendance in Washington and Idaho,” Indoor Air, 14 (5). 333-341, 2004. | ||
In article | View Article PubMed | ||
[59] | Seppänen, O. A., W. J. Fisk, and M. J. Mendell, “Association of Ventilation Rates and CO2 Concentrations with Health andOther Responses in Commercial and Institutional Buildings,” Indoor Air, 9 (4). 226-252, 1999. | ||
In article | View Article PubMed | ||
[60] | Daisey, J. M., W. J. Angell, and M. G. Apte, “Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information,” Indoor Air, 13 (1). 53-64, 2003. | ||
In article | View Article PubMed | ||
[61] | Ramachandran, G., J. L. Adgate, S. Banerjee, T. R. Church, D. Jones, A. Fredrickson, and K. Sexton, “Indoor air quality in two urban elementary schools--measurements of airborne fungi, carpet allergens, CO2, temperature, and relative humidity,” Journal of Occupational and Environmental Hygiene, 2 (11). 553-566, 2005. | ||
In article | View Article PubMed | ||
[62] | Polednik, B., “Particulate matter and student exposure in school classrooms in Lublin, Poland,” Environmental Research, 120 134-139, 2013. | ||
In article | View Article PubMed | ||
[63] | Parker, J. L., R. R. Larson, E. Eskelson, E. M. Wood, and J. M. Veranth, “Particle size distribution and composition in a mechanically ventilated school building during air pollution episodes,” Indoor Air, 18 (5). 386-393, 2008. | ||
In article | View Article PubMed | ||
[64] | Gusten, J., and O. Strindehag, “Experiences of measures taken to improve the air quality in schools,” Air Infiltration Review, 16 (3). 5-8, 1995. | ||
In article | |||
[65] | Offor, I. F., G. U. Adie, and G. R. E. E. Ana, “Review of Particulate Matter and Elemental Composition of Aerosols at Selected Locations in Nigeria from 1985 – 2015,” Journal of Health and Pollution, 6 (10). 1-18, 2016. | ||
In article | View Article PubMed PubMed | ||
[66] | Efe, S. I., “Spatial distribution of particulate air pollution in Nigerian cities: Implications for human health,” Journal of Environmental Health Research, 7 (2). 107-116, 2008. | ||
In article | |||
[67] | US-EPA, A Brief Guide to Mold, Moisture, and Your Home, U.S. Environmental Protection Agency: CreateSpace Independent Publishing Platform, 2017. | ||
In article | |||
[68] | WHO, WHO Guidelines for Indoor Air Quality: Selected Pollutants, World Health Organization: WHO, 2010. | ||
In article | |||
[69] | Penney, D. G., Carbon Monoxide Poisoning: Taylor & Francis, 2008. | ||
In article | View Article | ||
[70] | Mullin, R. C., Electrical Wiring Residential: Based on the 2005 National Electric Code: Thomson Delmar Learning, 2004. | ||
In article | |||
[71] | Wu, Y.-C., and S. A. Batterman, “Proximity of schools in Detroit, Michigan to automobile and truck traffic,” Journal of Exposure Science and Environmental Epidemiology, 16 457, 2006. | ||
In article | View Article PubMed | ||
[72] | Ashrae, Standard 55-2013 User's Manual: ANSI/ASHRAE Standard 55-2013, Thermal Environmental Conditions for Human Occupancy: ASHRAE Research, 2016. | ||
In article | |||
[73] | Beamish, L. A., E. Wine, and A. R. Osornio-Vargas, “Air pollution: An environmental factor contributing to intestinal disease,” Journal of Crohn's and Colitis, 5 (4). 279-286, 2011. | ||
In article | View Article PubMed | ||
[74] | Salim, S. Y., G. G. Kaplan, and K. L. Madsen, “Air pollution effects on the gut microbiota: a link between exposure and inflammatory disease,” Gut microbes, 5 (2). 215-219, 2014. | ||
In article | View Article PubMed PubMed | ||
[75] | Kish, L., N. Hotte, G. G. Kaplan, R. Vincent, R. Tso, M. Ganzle, K. P. Rioux, A. Thiesen, H. W. Barkema, E. Wine, and K. L. Madsen, “Environmental particulate matter induces murine intestinal inflammatory responses and alters the gut microbiome,” PLoS One, 8 (4). e62220, 2013. | ||
In article | View Article PubMed PubMed | ||
[76] | Salim, S. Y., J. Jovel, E. Wine, G. G. Kaplan, R. Vincent, A. Thiesen, H. W. Barkema, and K. L. Madsen, “Exposure to ingested airborne pollutant particulate matter increases mucosal exposure to bacteria and induces early onset of inflammation in neonatal IL-10-deficient mice,” Inflammatory Bowel Diseases, 20 (7). 1129-1138, 2014. | ||
In article | View Article PubMed | ||
[77] | Grigg, J., “Particulate matter exposure in children: relevance to chronic obstructive pulmonary disease,” Proceedings of the American Thoracic Society, 6 (7). 564-569, 2009. | ||
In article | View Article PubMed | ||
[78] | Peters, A., D. W. Dockery, J. E. Muller, and M. A. Mittleman, “Increased particulate air pollution and the triggering of myocardial infarction,” Circulation, 103 (23). 2810-2815, 2001. | ||
In article | View Article PubMed | ||
[79] | Kaplan, G. G., J. Hubbard, J. Korzenik, B. E. Sands, R. Panaccione, S. Ghosh, A. J. Wheeler, and P. J. Villeneuve, “The inflammatory bowel diseases and ambient air pollution: a novel association,” The American journal of gastroenterology, 105 (11). 2412-2419, 2010. | ||
In article | View Article PubMed PubMed | ||
[80] | Hart, J. E., F. Laden, R. C. Puett, K. H. Costenbader, and E. W. Karlson, “Exposure to traffic pollution and increased risk of rheumatoid arthritis,” Environmental Health Perspectives, 117 (7). 1065-1069, 2009. | ||
In article | View Article PubMed PubMed | ||
[81] | Tornqvist, H., N. L. Mills, M. Gonzalez, M. R. Miller, S. D. Robinson, I. L. Megson, W. Macnee, K. Donaldson, S. Soderberg, D. E. Newby, T. Sandstrom, and A. Blomberg, “Persistent endothelial dysfunction in humans after diesel exhaust inhalation,” American Journal of Respiratory and Critical Care Medicine, 176 (4). 395-400, 2007. | ||
In article | View Article PubMed | ||
[82] | Losacco, C., A. J. E. S. Perillo, and P. Research, “Particulate matter air pollution and respiratory impact on humans and animals,” 25 (34). 33901-33910, 2018. | ||
In article | View Article PubMed | ||
Published with license by Science and Education Publishing, Copyright © 2019 Aniefiok E. Ite, Thomas A. Harry, Clement O. Obadimu and Ifiok O. Ekwere
This work is licensed under a Creative Commons Attribution 4.0 International License. To view a copy of this license, visit
https://creativecommons.org/licenses/by/4.0/
[1] | Ite, A. E., and U. J. Ibok, “Gas Flaring and Venting Associated with Petroleum Exploration and Production in the Nigeria's Niger Delta,” American Journal of Environmental Protection, 1 (4). 70-77, 2013. | ||
In article | View Article | ||
[2] | Ite, A. E., U. J. Ibok, M. U. Ite, and S. W. Petters, “Petroleum Exploration and Production: Past and Present Environmental Issues in the Nigeria's Niger Delta,” American Journal of Environmental Protection, 1 (4). 78-90, 2013. | ||
In article | View Article | ||
[3] | Ite, A. E., U. F. Ufot, M. U. Ite, I. O. Isaac, and U. J. Ibok, “Petroleum Industry in Nigeria: Environmental Issues, National Environmental Legislation and Implementation of International Environmental Law,” American Journal of Environmental Protection, 4 (1). 21-37, 2016. | ||
In article | |||
[4] | Kampa, M., and E. Castanas, “Human health effects of air pollution,” Environmental Pollution, 151 (2). 362-367, 2008. | ||
In article | View Article PubMed | ||
[5] | Kelly, F. J., G. W. Fuller, H. A. Walton, and J. C. Fussell, “Monitoring air pollution: use of early warning systems for public health,” Respirology, 17 (1). 7-19, 2012. | ||
In article | View Article PubMed | ||
[6] | Lippmann, M., “Particulate matter (PM) air pollution and health: regulatory and policy implications,” Air Quality, Atmosphere & Health, 5 (2). 237-241, 2011. | ||
In article | View Article | ||
[7] | Ite, A. E., C. O. Ogunkunle, C. O. Obadimu, E. R. Asuaiko, and U. J. Ibok, “Particulate Matter and Staff Exposure in an Air-Conditioned Office in Akwa Ibom State University - Nigeria,” Journal of Atmospheric Pollution, 5 (1). 24-32, 2017. | ||
In article | View Article | ||
[8] | Cohen, A. J., H. R. Anderson, B. Ostro, K. D. Pandey, M. Krzyzanowski, N. Künzli, K. Gutschmidt, C. Pope III, I. Romieu, and J. M. Samet, “Urban Air Pollution,” Comparative Quantification of Health Risks: Global and Regional Burden of Disease Attributable to Selected Major Risk Factors, M. Ezzati, A. Lopez, A. Rodgers and C. J. L. Murray, eds., pp. 1353-1433, Geneva: World Health Organization, 2004. | ||
In article | |||
[9] | Wiseman, C. L. S., and F. Zereini, “Part I - Airborne Particulate Matter: Sources, Composition and Concentration,” Urban Airborne Particulate Matter: Origin, Chemistry, Fate and Health Impacts, F. Zereini and C. L. S. Wiseman, eds., pp. 1-2, Berlin, Heidelberg: Springer Berlin Heidelberg, 2011. | ||
In article | |||
[10] | Pöschl, U., “Atmospheric Aerosols: Composition, Transformation, Climate and Health Effects,” Angewandte Chemie International Edition, 44 (46). 7520-7540, 2005. | ||
In article | View Article PubMed | ||
[11] | Godwin, C., and S. Batterman, “Indoor air quality in Michigan schools,” Indoor Air, 17 (2). 109-121, 2007. | ||
In article | View Article PubMed | ||
[12] | Madureira, J., I. Paciência, C. Pereira, J. P. Teixeira, and E. d. O. Fernandes, “Indoor air quality in Portuguese schools: levels and sources of pollutants,” 26 (4). 526-537, 2016. | ||
In article | View Article PubMed | ||
[13] | Lee, S. C., and M. Chang, “Indoor and outdoor air quality investigation at schools in Hong Kong,” Chemosphere, 41 (1). 109-113, 2000. | ||
In article | View Article | ||
[14] | Fromme, H., D. Twardella, S. Dietrich, D. Heitmann, R. Schierl, B. Liebl, and H. Rüden, “Particulate matter in the indoor air of classrooms—exploratory results from Munich and surrounding area,” Atmospheric Environment, 41 (4). 854-866, 2007. | ||
In article | View Article | ||
[15] | Vilčeková, S., P. Kapalo, Ľ. Mečiarová, E. K. Burdová, and V. Imreczeová, “Investigation of Indoor Environment Quality in Classroom - Case Study,” Procedia Engineering, 190 496-503, 2017. | ||
In article | View Article | ||
[16] | Yousaf, A. R., and N. Khan, “The study of particulate matter concentration in schools of Lahore,” Nature Environment and Pollution Technology, 12 (2). 289-296, 2013. | ||
In article | |||
[17] | Moschandreas, D. J., and K. L. Vuilleumier, “ETS levels in hospitality environments satisfying ASHRAE standard 62-1989: “ventilation for acceptable indoor air quality”,” Atmospheric Environment, 33 (26). 4327-4340, 1999. | ||
In article | View Article | ||
[18] | Santamouris, M., A. Synnefa, M. Asssimakopoulos, I. Livada, K. Pavlou, M. Papaglastra, N. Gaitani, D. Kolokotsa, and V. Assimakopoulos, “Experimental investigation of the air flow and indoor carbon dioxide concentration in classrooms with intermittent natural ventilation,” Energy and Buildings, 40 (10). 1833-1843, 2008. | ||
In article | View Article | ||
[19] | Synnefa, A., E. Polichronaki, E. Papagiannopoulou, M. Santamouris, G. Mihalakakou, P. Doukas, P. A. Siskos, E. Bakeas, A. Dremetsika, A. Geranios, and A. Delakou, “An Experimental Investigation of the Indoor Air Quality in Fifteen School Buildings in Athens, Greece,” International Journal of Ventilation, 2 (3). 185-201, 2003. | ||
In article | View Article | ||
[20] | Jovanović, M., B. Vučićević, V. Turanjanin, M. Živković, and V. Spasojević, “Investigation of indoor and outdoor air quality of the classrooms at a school in Serbia,” Energy, 77 42-48, 2014. | ||
In article | View Article | ||
[21] | Almeida, S. M., N. Canha, A. Silva, M. d. C. Freitas, P. Pegas, C. Alves, M. Evtyugina, and C. A. Pio, “Children exposure to atmospheric particles in indoor of Lisbon primary schools,” Atmospheric Environment, 45 (40). 7594-7599, 2011. | ||
In article | View Article | ||
[22] | Yang, W., J. Sohn, J. Kim, B. Son, and J. Park, “Indoor air quality investigation according to age of the school buildings in Korea,” Journal of Environmental Management, 90 (1). 348-354, 2009. | ||
In article | View Article PubMed | ||
[23] | Verriele, M., C. Schoemaecker, B. Hanoune, N. Leclerc, S. Germain, V. Gaudion, and N. Locoge, “The MERMAID study: indoor and outdoor average pollutant concentrations in 10 low-energy school buildings in France,” 26 (5). 702-713, 2016. | ||
In article | View Article PubMed | ||
[24] | Cartieaux, E., M. A. Rzepka, and D. Cuny, “Qualité de l’air à l’intérieur des écoles,” Archives de Pediatrie, 18 (7). 789-796, 2011. | ||
In article | View Article PubMed | ||
[25] | Nkwocha, E. E., R. O. J. I. J. o. E. S. Egejuru, and Technology, “Effects of industrial air pollution on the respiratory health of children,” 5 (4). 509-516, 2008. | ||
In article | View Article | ||
[26] | Abdel-Salam, M. M. M., “Investigation of indoor air quality at urban schools in Qatar,” Indoor and Built Environment, 28 (2). 278-288, 2017. | ||
In article | View Article | ||
[27] | de Gennaro, G., P. R. Dambruoso, A. D. Loiotile, A. Di Gilio, P. Giungato, M. Tutino, A. Marzocca, A. Mazzone, J. Palmisani, and F. J. E. C. L. Porcelli, “Indoor air quality in schools,” 12 (4). 467-482, 2014. | ||
In article | View Article | ||
[28] | de Gennaro, G., P. R. Dambruoso, A. D. Loiotile, A. Di Gilio, P. Giungato, M. Tutino, A. Marzocca, A. Mazzone, J. Palmisani, and F. Porcelli, “Indoor air quality in schools,” Environmental Chemistry Letters, 12 (4). 467-482, 2014. | ||
In article | View Article | ||
[29] | Meininghaus, R., A. Kouniali, C. Mandin, and A. Cicolella, “Risk assessment of sensory irritants in indoor air—a case study in a French school,” Environment International, 28 (7). 553-557, 2003. | ||
In article | View Article | ||
[30] | Kim, K.-H., E. Kabir, and S. Kabir, “A review on the human health impact of airborne particulate matter,” Environment International, 74 136-143, 2015. | ||
In article | View Article PubMed | ||
[31] | Celo, V., and E. Dabek-Zlotorzynska, “Concentration and Source Origin of Trace Metals in PM2.5 Collected at Selected Canadian Sites within the Canadian National Air Pollution Surveillance Program,” Urban Airborne Particulate Matter: Origin, Chemistry, Fate and Health Impacts, F. Zereini and C. L. S. Wiseman, eds., pp. 19-38, Berlin, Heidelberg: Springer Berlin Heidelberg, 2011. | ||
In article | View Article | ||
[32] | Iavicoli, I., V. Leso, L. Fontana, and A. Bergamaschi, “Occupational Exposure to Urban Airborne Particulate Matter: A Review on Environmental Monitoring and Health Effects,” Urban Airborne Particulate Matter: Origin, Chemistry, Fate and Health Impacts, F. Zereini and C. L. S. Wiseman, eds., pp. 501-525, Berlin, Heidelberg: Springer Berlin Heidelberg, 2011. | ||
In article | View Article PubMed PubMed | ||
[33] | Jahn, H. J., A. Schneider, S. Breitner, R. Eißner, M. Wendisch, and A. Krämer, “Particulate matter pollution in the megacities of the Pearl River Delta, China – A systematic literature review and health risk assessment,” International Journal of Hygiene and Environmental Health, 214 (4). 281-295, 2011. | ||
In article | View Article PubMed | ||
[34] | Calkovska, A., and E. Herting, “Exogenous surfactant in respiratory distress syndrome,” Applied Technologies in Pulmonary Medicine, A. M. Esuinas, ed., pp. 205-209, Basel: Karger Publishers, 2010. | ||
In article | View Article | ||
[35] | Frew, A. J., S. R. Doffman, K. Hurt, and R. Buxton-homas, “Respiratory Disease,” Kumar & Clark Clinical Medicine, P. J. Kumar and M. L. Clark, eds., pp. 791-866, Saunders: Elsevier 2005. | ||
In article | |||
[36] | Guaita, R., M. Pichiule, T. Mate, C. Linares, and J. Diaz, “Short-term impact of particulate matter (PM(2.5)) on respiratory mortality in Madrid,” International Journal of Environmental Health Research, 21 (4). 260-274, 2011. | ||
In article | View Article PubMed | ||
[37] | Janssen, N. A. H., P. Fischer, M. Marra, C. Ameling, and F. R. Cassee, “Short-term effects of PM2.5, PM10 and PM2.5–10 on daily mortality in the Netherlands,” Science of the Total Environment, 463–464 20-26, 2013. | ||
In article | View Article PubMed | ||
[38] | Halonen, J. I., T. Lanki, T. Yli-Tuomi, P. Tiittanen, M. Kulmala, and J. Pekkanen, “Particulate air pollution and acute cardiorespiratory hospital admissions and mortality among the elderly,” Epidemiology, 20 (1). 143-153, 2009. | ||
In article | View Article PubMed | ||
[39] | Du, Y., X. Xu, M. Chu, Y. Guo, and J. Wang, “Air particulate matter and cardiovascular disease: the epidemiological, biomedical and clinical evidence,” Journal of Thoracic Disease, 8 (1). E8-E19, 2016. | ||
In article | |||
[40] | Brook, R. D., S. Rajagopalan, C. A. Pope, J. R. Brook, A. Bhatnagar, A. V. Diez-Roux, F. Holguin, Y. Hong, R. V. Luepker, and M. A. Mittleman, “Particulate matter air pollution and cardiovascular disease,” Circulation, 121 (21). 2331-2378, 2010. | ||
In article | View Article PubMed | ||
[41] | Pope, C. A., and D. W. Dockery, “Health Effects of Fine Particulate Air Pollution: Lines that Connect,” Journal of the Air & Waste Management Association, 56 (6). 709-742, 2006. | ||
In article | View Article | ||
[42] | Davidson, C. I., R. F. Phalen, and P. A. Solomon, “Airborne Particulate Matter and Human Health: A Review,” Aerosol Science and Technology, 39 (8). 737-749, 2005. | ||
In article | View Article | ||
[43] | Linares, C., and J. Diaz, “Short-term effect of concentrations of fine particulate matter on hospital admissions due to cardiovascular and respiratory causes among the over-75 age group in Madrid, Spain,” Public Health, 124 (1). 28-36, 2010. | ||
In article | View Article PubMed | ||
[44] | Strak, M., G. Hoek, M. Steenhof, E. Kilinc, K. J. Godri, I. Gosens, I. S. Mudway, R. van Oerle, H. M. H. Spronk, F. R. Cassee, F. J. Kelly, R. M. Harrison, B. Brunekreef, E. Lebret, and N. A. H. Janssen, “Components of ambient air pollution affect thrombin generation in healthy humans: the RAPTES project,” Occupational and Environmental Medicine, 70 (5). 332-340, 2013. | ||
In article | View Article PubMed | ||
[45] | Brunekreef, B., and S. T. Holgate, “Air pollution and health,” Lancet, 360 (9341). 1233-1242, 2002. | ||
In article | View Article | ||
[46] | Heudorf, U., V. Neitzert, and J. Spark, “Particulate matter and carbon dioxide in classrooms – The impact of cleaning and ventilation,” International Journal of Hygiene and Environmental Health, 212 (1). 45-55, 2009. | ||
In article | View Article PubMed | ||
[47] | Graudenz, G. S., C. H. Oliveira, A. Tribess, C. Mendes, M. R. D. O. Latorre, and J. Kalil, “Association of air-conditioning with respiratory symptoms in office workers in tropical climate,” Indoor Air, 15 (1). 62-66, 2005. | ||
In article | View Article PubMed | ||
[48] | Al-Hemoud, A., L. Al-Awadi, M. Al-Rashidi, K. A. Rahman, A. Al-Khayat, and W. Behbehani, “Comparison of indoor air quality in schools: Urban vs. Industrial 'oil & gas' zones in Kuwait,” Building and Environment, 122 50-60, 2017. | ||
In article | View Article | ||
[49] | Cavaleiro Rufo, J., J. Madureira, I. Paciencia, K. Slezakova, C. Pereira Mdo, L. Aguiar, J. P. Teixeira, A. Moreira, and E. Oliveira Fernandes, “Children exposure to indoor ultrafine particles in urban and rural school environments,” Environ Sci Pollut Res Int, 23 (14). 13877-13885, 2016. | ||
In article | View Article PubMed | ||
[50] | Jo, W.-K., and J.-Y. Lee, “Indoor and outdoor levels of respirable particulates (PM10) and Carbon Monoxide (CO) in high-rise apartment buildings,” Atmospheric Environment, 40 (32). 6067-6076, 2006. | ||
In article | View Article | ||
[51] | WHO, Air Quality Guidelines: Global Update 2005: Particulate Matter, Ozone, Nitrogen dioxide, and Sulfur dioxide, Copenhagen, Denmark: World Health Organization, 2006. | ||
In article | |||
[52] | Goyal, R., and M. Khare, “Indoor–outdoor concentrations of RSPM in classroom of a naturally ventilated school building near an urban traffic roadway,” Atmospheric Environment, 43 (38). 6026-6038, 2009. | ||
In article | View Article | ||
[53] | Tippayawong, N., P. Khuntong, C. Nitatwichit, Y. Khunatorn, and C. Tantakitti, “Indoor/outdoor relationships of size-resolved particle concentrations in naturally ventilated school environments,” Building and Environment, 44 (1). 188-197, 2009. | ||
In article | View Article | ||
[54] | Chithra, V. S., and S. M. Shiva Nagendra, “Indoor air quality investigations in a naturally ventilated school building located close to an urban roadway in Chennai, India,” Building and Environment, 54 159-167, 2012. | ||
In article | View Article | ||
[55] | Thatcher, T. L., and D. W. Layton, “Deposition, resuspension, and penetration of particles within a residence,” Atmospheric Environment, 29 (13). 1487-1497, 1995. | ||
In article | View Article | ||
[56] | Kalimeri, K. K., D. E. Saraga, V. D. Lazaridis, N. A. Legkas, D. A. Missia, E. I. Tolis, and J. G. Bartzis, “Indoor air quality investigation of the school environment and estimated health risks: Two-season measurements in primary schools in Kozani, Greece,” Atmospheric Pollution Research, 7 (6). 1128-1142, 2016. | ||
In article | View Article | ||
[57] | Mendell, M. J., and G. A. Heath, “Do indoor pollutants and thermal conditions in schools influence student performance? A critical review of the literature,” Indoor Air, 15 (1). 27-52, 2005. | ||
In article | View Article PubMed | ||
[58] | Shendell, D. G., R. Prill, W. J. Fisk, M. G. Apte, D. Blake, and D. Faulkner, “Associations between classroom CO2 concentrations and student attendance in Washington and Idaho,” Indoor Air, 14 (5). 333-341, 2004. | ||
In article | View Article PubMed | ||
[59] | Seppänen, O. A., W. J. Fisk, and M. J. Mendell, “Association of Ventilation Rates and CO2 Concentrations with Health andOther Responses in Commercial and Institutional Buildings,” Indoor Air, 9 (4). 226-252, 1999. | ||
In article | View Article PubMed | ||
[60] | Daisey, J. M., W. J. Angell, and M. G. Apte, “Indoor air quality, ventilation and health symptoms in schools: an analysis of existing information,” Indoor Air, 13 (1). 53-64, 2003. | ||
In article | View Article PubMed | ||
[61] | Ramachandran, G., J. L. Adgate, S. Banerjee, T. R. Church, D. Jones, A. Fredrickson, and K. Sexton, “Indoor air quality in two urban elementary schools--measurements of airborne fungi, carpet allergens, CO2, temperature, and relative humidity,” Journal of Occupational and Environmental Hygiene, 2 (11). 553-566, 2005. | ||
In article | View Article PubMed | ||
[62] | Polednik, B., “Particulate matter and student exposure in school classrooms in Lublin, Poland,” Environmental Research, 120 134-139, 2013. | ||
In article | View Article PubMed | ||
[63] | Parker, J. L., R. R. Larson, E. Eskelson, E. M. Wood, and J. M. Veranth, “Particle size distribution and composition in a mechanically ventilated school building during air pollution episodes,” Indoor Air, 18 (5). 386-393, 2008. | ||
In article | View Article PubMed | ||
[64] | Gusten, J., and O. Strindehag, “Experiences of measures taken to improve the air quality in schools,” Air Infiltration Review, 16 (3). 5-8, 1995. | ||
In article | |||
[65] | Offor, I. F., G. U. Adie, and G. R. E. E. Ana, “Review of Particulate Matter and Elemental Composition of Aerosols at Selected Locations in Nigeria from 1985 – 2015,” Journal of Health and Pollution, 6 (10). 1-18, 2016. | ||
In article | View Article PubMed PubMed | ||
[66] | Efe, S. I., “Spatial distribution of particulate air pollution in Nigerian cities: Implications for human health,” Journal of Environmental Health Research, 7 (2). 107-116, 2008. | ||
In article | |||
[67] | US-EPA, A Brief Guide to Mold, Moisture, and Your Home, U.S. Environmental Protection Agency: CreateSpace Independent Publishing Platform, 2017. | ||
In article | |||
[68] | WHO, WHO Guidelines for Indoor Air Quality: Selected Pollutants, World Health Organization: WHO, 2010. | ||
In article | |||
[69] | Penney, D. G., Carbon Monoxide Poisoning: Taylor & Francis, 2008. | ||
In article | View Article | ||
[70] | Mullin, R. C., Electrical Wiring Residential: Based on the 2005 National Electric Code: Thomson Delmar Learning, 2004. | ||
In article | |||
[71] | Wu, Y.-C., and S. A. Batterman, “Proximity of schools in Detroit, Michigan to automobile and truck traffic,” Journal of Exposure Science and Environmental Epidemiology, 16 457, 2006. | ||
In article | View Article PubMed | ||
[72] | Ashrae, Standard 55-2013 User's Manual: ANSI/ASHRAE Standard 55-2013, Thermal Environmental Conditions for Human Occupancy: ASHRAE Research, 2016. | ||
In article | |||
[73] | Beamish, L. A., E. Wine, and A. R. Osornio-Vargas, “Air pollution: An environmental factor contributing to intestinal disease,” Journal of Crohn's and Colitis, 5 (4). 279-286, 2011. | ||
In article | View Article PubMed | ||
[74] | Salim, S. Y., G. G. Kaplan, and K. L. Madsen, “Air pollution effects on the gut microbiota: a link between exposure and inflammatory disease,” Gut microbes, 5 (2). 215-219, 2014. | ||
In article | View Article PubMed PubMed | ||
[75] | Kish, L., N. Hotte, G. G. Kaplan, R. Vincent, R. Tso, M. Ganzle, K. P. Rioux, A. Thiesen, H. W. Barkema, E. Wine, and K. L. Madsen, “Environmental particulate matter induces murine intestinal inflammatory responses and alters the gut microbiome,” PLoS One, 8 (4). e62220, 2013. | ||
In article | View Article PubMed PubMed | ||
[76] | Salim, S. Y., J. Jovel, E. Wine, G. G. Kaplan, R. Vincent, A. Thiesen, H. W. Barkema, and K. L. Madsen, “Exposure to ingested airborne pollutant particulate matter increases mucosal exposure to bacteria and induces early onset of inflammation in neonatal IL-10-deficient mice,” Inflammatory Bowel Diseases, 20 (7). 1129-1138, 2014. | ||
In article | View Article PubMed | ||
[77] | Grigg, J., “Particulate matter exposure in children: relevance to chronic obstructive pulmonary disease,” Proceedings of the American Thoracic Society, 6 (7). 564-569, 2009. | ||
In article | View Article PubMed | ||
[78] | Peters, A., D. W. Dockery, J. E. Muller, and M. A. Mittleman, “Increased particulate air pollution and the triggering of myocardial infarction,” Circulation, 103 (23). 2810-2815, 2001. | ||
In article | View Article PubMed | ||
[79] | Kaplan, G. G., J. Hubbard, J. Korzenik, B. E. Sands, R. Panaccione, S. Ghosh, A. J. Wheeler, and P. J. Villeneuve, “The inflammatory bowel diseases and ambient air pollution: a novel association,” The American journal of gastroenterology, 105 (11). 2412-2419, 2010. | ||
In article | View Article PubMed PubMed | ||
[80] | Hart, J. E., F. Laden, R. C. Puett, K. H. Costenbader, and E. W. Karlson, “Exposure to traffic pollution and increased risk of rheumatoid arthritis,” Environmental Health Perspectives, 117 (7). 1065-1069, 2009. | ||
In article | View Article PubMed PubMed | ||
[81] | Tornqvist, H., N. L. Mills, M. Gonzalez, M. R. Miller, S. D. Robinson, I. L. Megson, W. Macnee, K. Donaldson, S. Soderberg, D. E. Newby, T. Sandstrom, and A. Blomberg, “Persistent endothelial dysfunction in humans after diesel exhaust inhalation,” American Journal of Respiratory and Critical Care Medicine, 176 (4). 395-400, 2007. | ||
In article | View Article PubMed | ||
[82] | Losacco, C., A. J. E. S. Perillo, and P. Research, “Particulate matter air pollution and respiratory impact on humans and animals,” 25 (34). 33901-33910, 2018. | ||
In article | View Article PubMed | ||