Cataract blindness presents an enormous problem in terms of public health burden, economic loss and social burden. A hospital based retrospective study reviewed the medical data of 520 patients (mean age 68.42±11.77 years) to detect gender based comparison of axial length, corneal curvature and power of intraocular lens that was implanted in patients undergoing cataract surgery in Western Nepal. A significant inter-gender differences was seen in age, axial length, keratometric values and intraocular lens power between the two groups (p<0.05). Females had shorter axial length (22.85±0.86 mm) and steeper corneal curvature (K1: 43.79±1.51 D, K2: 44.46±1.54 D) compared to males (23.04±1.01 mm, K1: 43.51±1.40 D, K2: 44.16±1.40 D). The axial length had a decreasing trend with increasing age in both the sexes. The average power of the intraocular lens was 21.28±1.91 D. In conclusion, the axial length of Nepalese population was comparable to Indian and Pakistani population. However, it was slightly shorter than Whites, Middle-Eastern and some Asian population. The keratometric value ranges from 38.75-50.00 D. Maximum number of patients required intraocular lens of power between 20.00-22.99 D
| [1] | Pascolini D, Mariotti SP. Global estimates of visual impairment: 2010. Br J Ophthalmol. 2012; 96; 614-18.View Article PubMed |
| [2] | Rainer G, Menapace R, Vass C, Annen D, Findl O, Schmetterer K. Corneal shape changes after temporal and superolateral 3.0 mm clear corneal incisions. J Cataract Refract Surg. 1999; 25 (8): 1121-1126.View Article |
| [3] | Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 1992; 18 (2); 125-9.View Article |
| [4] | Olsen T. Theoretical approach to intraocular lens calculation using Gaussian optics. J Cataract Refract Surg. 1987; 13 (2); 141-5.View Article |
| [5] | Midelfart A. Women and men – same eyes?, Acta Ophthalmol. Scand. 1996; 74: 589-592.View Article PubMed |
| [6] | Richard SC, Brodstein DE, Olson RJ, Richards WL, Differences between men and women as related to intraocular lens implantation. Ophthalmic Surg. 1986; 17; 82-87. |
| [7] | Yeh LK, Tan H, Huang SC, Tsai SY, Tsai RJ. Annual database of Intraocular Lens Power in Taiwanese Population. Chang Gung Med J. 2004; 27 (1); 44-48. PubMed |
| [8] | Nizamani NB, Surhio SA, Memon S, Talpur KI. Axial Length Variability in Cataract Surgery. Journal of the College of Physicians and Surgeons Pakistan. 2014; 24 (12): 918-921. PubMed |
| [9] | Rashid H, Naseem A, Rahman F. Two Years Review of Intraocular Lens Power Calculation in Ophthalmology Department of Saidu Teaching Hospital, Swat. Pak J Ophthalmol. 2007; 23 (3): 122-125. |
| [10] | Wani JS, Parray SI, Keng MQ, Majid O, Maqbool A. Profile of axial length in Kashmiri population with cataract. International Journal of Medical Science and Public Health. 2014; 3 (9): 1120-22.View Article |
| [11] | Midelfart A, Aamo B. Ocular parameters in elderly in Norway,” Acta Ophthalmologica, 1994; 72: 61-66.View Article PubMed |
| [12] | Nangia V, Jonas JB, Sinha A, Kulkarni M, Jonas SP. Ocular Axial Length and its Associations in an Adult Population of Central Rural India: The Central India Eye and Medical Study. Ophthalmology. 2010; 117: 1360-66.View Article PubMed |
| [13] | Fotedar R, Wang JJ, Burlutsky G, Morgan IG, Rose K, Wong TY, Mitchell P. Distribution of axial length and ocular biometry measured using partial coherence laser interferometry (IOL Master) in an older white population. Ophthalmology. 2010; 117 (3): 417-23.View Article PubMed |
| [14] | Leighton DA, Tomlinson A, Changes in axial length and other dimensions of the eyeball with increasing age. Acta Ophthalmologica. 1972; 50: 815-26.View Article PubMed |
| [15] | Lee KE, Klein BEK, Klein R, Quandt Z, Wong TY. Age, Stature, and Education Associations with ocular dimensions in an older white population. Arch Ophthalmol. 2009; 127 (1): 88-93.View Article PubMed |
| [16] | Hashemi H, Khabazkhoob M, Miraftab M, Emamian MH, Shariati M, Abdolahinia T, Fotouhi A. The distribution of axial length, anterior chamber depth, lens thickness, and vitreous chamber depth in an adult population of Shahroud, Iran. BMC Ophthalmology. 2012; 12: 1-8.View Article PubMed |
| [17] | Reyes KB, Uy HS, “Refractive errors in Filipino eyes in a single-center study population. Philipp J Ophthalmol. 2010; 35 (2). 50-55. |
| [18] | Wong TY, Foster PJ, Tielsch JM, Johnson GJ, Seah SK. Variations in ocular biometry in an adult Chinese population in Singapore: the Tanjong Pagar Survey. Invest Ophthalmol Vis Sci. 2001; 42 (1): 73-80. PubMed |
| [19] | Lim KJ, Hyung SM, Youn DH. Ocular dimensions with aging in normal eyes. Korean J Ophthalmol. 1992; 6: 19-31.View Article PubMed |
| [20] | Foster PJ, Broadway DC, Hayat S, Luben R, Datzell N, Bingham S, Wareham NJ, Khaw KT. Refractive error, axial length and anterior chamber depth of the eye in British adults: the EPIC-Norfolk Eye Study. Br J Ophthalmol. 2010; 94; 827-830.View Article PubMed |
| [21] | Chen W, Zuo C, Chen C, Su J, Luo L, Congdon N, Liu Y. Prevalence of corneal astigmatism before cataract surgery in Chinese patients. J Cataract Refract Surg. 2013; 39: 188-192.View Article PubMed |
| [22] | Behndig A, Montan P, Lundström M, Zetterström C, Kugelberg M. Gender differences in biometry prediction error and intra-ocular lens power calculation formula. Acta Ophthalmologica. 2014; 92: 759-63.View Article PubMed |
| [23] | Rubido JS, Mallen EAH, Gilmartin B, Wolffsohn JS. A new non-contact optical device for ocular biometry. Br J Ophthalmol. 2002; 86; 458-462.View Article |
| [24] | Roy A, Kar M, Mandal D, Ray RS, Kar C. Variation of Axial Ocular Dimensions with Age, Sex, Height, BMI-and Their relation to Refractive Status. Journal of Clinical and Diagnostic Research. 2015; 9 (1); AC01-AC04. PubMed |